Sitep

discover the SITEP range also for rental or leasing

Retarder Proofers

SITEP retarder proofers are designed to intelligently and programmably manage the leavening stop and restart phases, allowing perfect production planning and ensuring consistent quality of the final product.

Thanks to the uniform distribution of air and the automatic temperature and humidity regulation system, the cells allow the dough to develop without the formation of a surface crust and without loss of hydration. The integrated software allows you to precisely program the different stages of retarding, adapting them to the specific needs of the laboratory.

Models for 95 Series

MODEL SERIES WORKING TEMPERATURE (°C) INTERNAL DIMENSIONS EXTERNAL DIMENSIONS TROLLEY CAPACITY VOLTAGE POWER (KW) CLEAR PASSAGE (CM)
1K 95 Series -9° / +45° 81x90x200h 93x107x232h 2 (60x40) or 1 (60x80) 230V - 1 - 50Hz 2,5 77x197
95×135 95 Series -9° / +45° 83x113x210h 95x135x255h 2 (60x40) or 1 (60x80) 230V - 1 - 50Hz 2,5 77x200
95×175 95 Series -9° / +45° 83x153x210h 95x175x255h 3 (60x40) or 1 (60x80) 400V - 3 - 50Hz 5 77x200
95×215 95 Series -9° / +45° 83x193x210h 95x215x255h 4 (60x40) or 2 (60x80) 400V - 3 - 50Hz 7 77x200
95×255 95 Series -9° / +45° 83x233x210h 95x255x255h 5 (60x40) or 2 (60x80) 400V - 3 - 50Hz 7 77x200
95×295 95 Series -9° / +45° 83x273x210h 95x295x255h 6 (60x40) or 3 (60x80) 400V - 3 - 50Hz 7 77x200
95×335 95 Series -9° / +45° 83x313x210h 95x335x255h 7 (60x40) or 3 (60x80) 400V - 3 - 50Hz 7 77x200

Models for 95 Series

1K
SERIES
95 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
81x90x200h
EXTERNAL DIMENSIONS
93x107x232h
TROLLEY CAPACITY
2 (60x40) or 1 (60x80)
VOLTAGE
230V - 1 - 50Hz
POWER (KW)
2,5
NET SPAN (CM)
77x197
95×135
SERIES
95 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
83x113x210h
EXTERNAL DIMENSIONS
95x135x255h
TROLLEY CAPACITY
2 (60x40) or 1 (60x80)
VOLTAGE
230V - 1 - 50Hz
POWER (KW)
2,5
NET SPAN (CM)
77x200
95×175
SERIES
95 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
83x153x210h
EXTERNAL DIMENSIONS
95x175x255h
TROLLEY CAPACITY
3 (60x40) or 1 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
5
NET SPAN (CM)
77x200
95×215
SERIES
95 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
83x193x210h
EXTERNAL DIMENSIONS
95x215x255h
TROLLEY CAPACITY
4 (60x40) or 2 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
77x200
95×255
SERIES
95 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
83x233x210h
EXTERNAL DIMENSIONS
95x255x255h
TROLLEY CAPACITY
5 (60x40) or 2 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
77x200
95×295
SERIES
95 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
83x273x210h
EXTERNAL DIMENSIONS
95x295x255h
TROLLEY CAPACITY
6 (60x40) or 3 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
77x200
95×335
SERIES
95 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
83x313x210h
EXTERNAL DIMENSIONS
95x335x255h
TROLLEY CAPACITY
7 (60x40) or 3 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
77x200

Models for 115 Series

MODEL SERIES WORKING TEMPERATURE (°C) INTERNAL DIMENSIONS EXTERNAL DIMENSIONS TROLLEY CAPACITY VOLTAGE POWER (KW) CLEAR PASSAGE (CM)
115×135 115 Series -9° / +45° 103x113x210h 115x135x255h 2 (60x40) or 1 (60x80) 400V - 3 - 50Hz 7 90x200
115×175 115 Series -9° / +45° 103x153x210h 115x175x255h 5 (60x40) or 2 (60x80) 400V - 3 - 50Hz 7 90x200
115×215 115 Series -9° / +45° 103x193x210h 115x215x255h 6 (60x40) or 3 (60x80) 400V - 3 - 50Hz 7 90x200
115×255 115 Series -9° / +45° 103x233x210h 115x255x255h 7 (60x40) or 3 (60x80) 400V - 3 - 50Hz 7 90x200
115×295 115 Series -9° / +45° 103x273x210h 115x295x255h 8 (60x40) or 4 (60x80) 400V - 3 - 50Hz 7 90x200
115×335 115 Series -9° / +45° 103x313x210h 115x335x255h 9 (60x40) or 4 (60x80) 400V - 3 - 50Hz 7 90x200

Models for 115 Series

115×135
SERIES
115 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
103x113x210h
EXTERNAL DIMENSIONS
115x135x255h
TROLLEY CAPACITY
2 (60x40) or 1 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
90x200
115×175
SERIES
115 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
103x153x210h
EXTERNAL DIMENSIONS
115x175x255h
TROLLEY CAPACITY
5 (60x40) or 2 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
90x200
115×215
SERIES
115 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
103x193x210h
EXTERNAL DIMENSIONS
115x215x255h
TROLLEY CAPACITY
6 (60x40) or 3 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
90x200
115×255
SERIES
115 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
103x233x210h
EXTERNAL DIMENSIONS
115x255x255h
TROLLEY CAPACITY
7 (60x40) or 3 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
90x200
115×295
SERIES
115 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
103x273x210h
EXTERNAL DIMENSIONS
115x295x255h
TROLLEY CAPACITY
8 (60x40) or 4 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
90x200
115×335
SERIES
115 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
103x313x210h
EXTERNAL DIMENSIONS
115x335x255h
TROLLEY CAPACITY
9 (60x40) or 4 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
90x200

Models for 135 Series

MODEL SERIES WORKING TEMPERATURE (°C) INTERNAL DIMENSIONS EXTERNAL DIMENSIONS TROLLEY CAPACITY VOLTAGE POWER (KW) CLEAR PASSAGE (CM)
135×135 135 Series -9° / +45° 123x113x210h 135x135x255h 3 (60x40) or 1 (60x80) 400V - 3 - 50Hz 7 100x200
135×175 135 Series -9° / +45° 123x153x210h 135x175x255h 4 (60x40) or 2 (60x80) 400V - 3 - 50Hz 7 100x200
135×215 135 Series -9° / +45° 123x193x210h 135x215x255h 6 (60x40) or 3 (60x80) 400V - 3 - 50Hz 7 100x200
135×255 135 Series -9° / +45° 123x233x210h 135x255x255h 7 (60x40) or 3 (60x80) 400V - 3 - 50Hz 7 100x200
135×295 135 Series -9° / +45° 123x273x210h 135x295x255h 8 (60x40) or 4 (60x80) 400V - 3 - 50Hz 7 100x200
135×335 135 Series -9° / +45° 123x313x210h 135x335x255h 9 (60x40) or 4 (60x80) 400V - 3 - 50Hz 7 100x200

Models for 135 Series

135×135
SERIES
135 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
123x113x210h
EXTERNAL DIMENSIONS
135x135x255h
TROLLEY CAPACITY
3 (60x40) or 1 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
135×175
SERIES
135 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
123x153x210h
EXTERNAL DIMENSIONS
135x175x255h
TROLLEY CAPACITY
4 (60x40) or 2 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
135×215
SERIES
135 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
123x193x210h
EXTERNAL DIMENSIONS
135x215x255h
TROLLEY CAPACITY
6 (60x40) or 3 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
135×255
SERIES
135 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
123x233x210h
EXTERNAL DIMENSIONS
135x255x255h
TROLLEY CAPACITY
7 (60x40) or 3 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
135×295
SERIES
135 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
123x273x210h
EXTERNAL DIMENSIONS
135x295x255h
TROLLEY CAPACITY
8 (60x40) or 4 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
135×335
SERIES
135 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
123x313x210h
EXTERNAL DIMENSIONS
135x335x255h
TROLLEY CAPACITY
9 (60x40) or 4 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200

Models for 175 Series

MODEL SERIES WORKING TEMPERATURE (°C) INTERNAL DIMENSIONS EXTERNAL DIMENSIONS TROLLEY CAPACITY VOLTAGE POWER (KW) CLEAR PASSAGE (CM)
175×135 175 Series -9° / +45° 163x113x210h 175x135x255h 5 (60x40) or 2 (60x80) 400V - 3 - 50Hz 7 100x200
175×175 175 Series -9° / +45° 163x153x210h 175x175x255h 6 (60x40) or 3 (60x80) 400V - 3 - 50Hz 7 100x200
175×215 175 Series -9° / +45° 163x193x210h 175x215x255h 8 (60x40) or 4 (60x80) 400V - 3 - 50Hz 7 100x200
175×255 175 Series -9° / +45° 163x233x210h 175x255x255h 7 (60x40) or 5 (60x80) 400V - 3 - 50Hz 10 100x200
175×295 175 Series -9° / +45° 163x273x210h 175x295x255h 10 (60x40) or 6 (60x80) 400V - 3 - 50Hz 10 100x200
175×335 175 Series -9° / +45° 163x313x210h 175x335x255h 12 (60x40) or 7 (60x80) 400V - 3 - 50Hz 13 100x200

Models for 175 Series

175×135
SERIES
175 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
163x113x210h
EXTERNAL DIMENSIONS
175x135x255h
TROLLEY CAPACITY
5 (60x40) or 2 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
175×175
SERIES
175 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
163x153x210h
EXTERNAL DIMENSIONS
175x175x255h
TROLLEY CAPACITY
6 (60x40) or 3 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
175×215
SERIES
175 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
163x193x210h
EXTERNAL DIMENSIONS
175x215x255h
TROLLEY CAPACITY
8 (60x40) or 4 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
175×255
SERIES
175 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
163x233x210h
EXTERNAL DIMENSIONS
175x255x255h
TROLLEY CAPACITY
7 (60x40) or 5 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
10
NET SPAN (CM)
100x200
175×295
SERIES
175 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
163x273x210h
EXTERNAL DIMENSIONS
175x295x255h
TROLLEY CAPACITY
10 (60x40) or 6 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
10
NET SPAN (CM)
100x200
175×335
SERIES
175 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
163x313x210h
EXTERNAL DIMENSIONS
175x335x255h
TROLLEY CAPACITY
12 (60x40) or 7 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
13
NET SPAN (CM)
100x200

Models for 215 Series

MODEL SERIES WORKING TEMPERATURE (°C) INTERNAL DIMENSIONS EXTERNAL DIMENSIONS TROLLEY CAPACITY VOLTAGE POWER (KW) CLEAR PASSAGE (CM)
215×135 215 Series -9° / +45° 203x113x210h 215x135x255h 6 (60x40) or 3 (60x80) 400V - 3 - 50Hz 7 100x200
215×175 215 Series -9° / +45° 203x153x210h 215x175x255h 8 (60x40) or 4 (60x80) 400V - 3 - 50Hz 7 100x200
215×215 215 Series -9° / +45° 203x193x210h 215x215x255h 10 (60x40) or 6 (60x80) 400V - 3 - 50Hz 10 100x200
215×255 215 Series -9° / +45° 203x233x210h 215x255x255h 12 (60x40) or 6 (60x80) 400V - 3 - 50Hz 10 100x200
215×295 215 Series -9° / +45° 203x273x210h 215x295x255h 12 (60x40) or 8 (60x80) 400V - 3 - 50Hz 13 100x200
215×335 215 Series -9° / +45° 203x313x210h 215x335x255h 14 (60x40) or 9 (60x80) 400V - 3 - 50Hz 13 100x200

Models for 215 Series

215×135
SERIES
215 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
203x113x210h
EXTERNAL DIMENSIONS
215x135x255h
TROLLEY CAPACITY
6 (60x40) or 3 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
215×175
SERIES
215 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
203x153x210h
EXTERNAL DIMENSIONS
215x175x255h
TROLLEY CAPACITY
8 (60x40) or 4 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
215×215
SERIES
215 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
203x193x210h
EXTERNAL DIMENSIONS
215x215x255h
TROLLEY CAPACITY
10 (60x40) or 6 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
10
NET SPAN (CM)
100x200
215×255
SERIES
215 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
203x233x210h
EXTERNAL DIMENSIONS
215x255x255h
TROLLEY CAPACITY
12 (60x40) or 6 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
10
NET SPAN (CM)
100x200
215×295
SERIES
215 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
203x273x210h
EXTERNAL DIMENSIONS
215x295x255h
TROLLEY CAPACITY
12 (60x40) or 8 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
13
NET SPAN (CM)
100x200
215×335
SERIES
215 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
203x313x210h
EXTERNAL DIMENSIONS
215x335x255h
TROLLEY CAPACITY
14 (60x40) or 9 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
13
NET SPAN (CM)
100x200

Models for 255 Series

MODEL SERIES WORKING TEMPERATURE (°C) INTERNAL DIMENSIONS EXTERNAL DIMENSIONS TROLLEY CAPACITY VOLTAGE POWER (KW) CLEAR PASSAGE (CM)
255×135 255 Series -9° / +45° 243x113x210h 255x135x255h 6 (60x40) or 3 (60x80) 400V - 3 - 50Hz 7 100x200
255×175 255 Series -9° / +45° 243x153x210h 255x175x255h 8 (60x40) or 4 (60x80) 400V - 3 - 50Hz 10 100x200
255×215 255 Series -9° / +45° 243x193x210h 255x215x255h 12 (60x40) or 6 (60x80) 400V - 3 - 50Hz 10 100x200
255×255 255 Series -9° / +45° 243x233x210h 255x255x255h 12 (60x40) or 6 (60x80) 400V - 3 - 50Hz 10 100x200
255×295 255 Series -9° / +45° 243x273x210h 255x295x255h 12 (60x40) or 9 (60x80) 400V - 3 - 50Hz 13 100x200
255×335 255 Series -9° / +45° 243x313x210h 255x335x255h 18 (60x40) or 9 (60x80) 400V - 3 - 50Hz 13 100x200

Models for 255 Series

255×135
SERIES
255 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
243x113x210h
EXTERNAL DIMENSIONS
255x135x255h
TROLLEY CAPACITY
6 (60x40) or 3 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
255×175
SERIES
255 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
243x153x210h
EXTERNAL DIMENSIONS
255x175x255h
TROLLEY CAPACITY
8 (60x40) or 4 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
10
NET SPAN (CM)
100x200
255×215
SERIES
255 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
243x193x210h
EXTERNAL DIMENSIONS
255x215x255h
TROLLEY CAPACITY
12 (60x40) or 6 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
10
NET SPAN (CM)
100x200
255×255
SERIES
255 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
243x233x210h
EXTERNAL DIMENSIONS
255x255x255h
TROLLEY CAPACITY
12 (60x40) or 6 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
10
NET SPAN (CM)
100x200
255×295
SERIES
255 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
243x273x210h
EXTERNAL DIMENSIONS
255x295x255h
TROLLEY CAPACITY
12 (60x40) or 9 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
13
NET SPAN (CM)
100x200
255×335
SERIES
255 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
243x313x210h
EXTERNAL DIMENSIONS
255x335x255h
TROLLEY CAPACITY
18 (60x40) or 9 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
13
NET SPAN (CM)
100x200

Models for 295 Series

MODEL SERIES WORKING TEMPERATURE (°C) INTERNAL DIMENSIONS EXTERNAL DIMENSIONS TROLLEY CAPACITY VOLTAGE POWER (KW) CLEAR PASSAGE (CM)
295×135 295 Series -9° / +45° 283x113x210h 295x135x255h 8 (60x40) or 4 (60x80) 400V - 3 - 50Hz 7 100x200
295×175 295 Series -9° / +45° 283x153x210h 295x175x255h 10 (60x40) or 6 (60x80) 400V - 3 - 50Hz 10 100x200
295×215 295 Series -9° / +45° 283x193x210h 295x215x255h 12 (60x40) or 8 (60x80) 400V - 3 - 50Hz 13 100x200
295×255 295 Series -9° / +45° 283x233x210h 295x255x255h 15 (60x40) or 9 (60x80) 400V - 3 - 50Hz 13 100x200
295×295 295 Series -9° / +45° 283x273x210h 295x295x255h 24 (60x40) or 12 (60x80) 400V - 3 - 50Hz 13 100x200
295×335 295 Series -9° / +45° 283x313x210h 295x335x255h 24 (60x40) or 12 (60x80) 400V - 3 - 50Hz 13 100x200

Models for 295 Series

295×135
SERIES
295 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
283x113x210h
EXTERNAL DIMENSIONS
295x135x255h
TROLLEY CAPACITY
8 (60x40) or 4 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
7
NET SPAN (CM)
100x200
295×175
SERIES
295 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
283x153x210h
EXTERNAL DIMENSIONS
295x175x255h
TROLLEY CAPACITY
10 (60x40) or 6 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
10
NET SPAN (CM)
100x200
295×215
SERIES
295 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
283x193x210h
EXTERNAL DIMENSIONS
295x215x255h
TROLLEY CAPACITY
12 (60x40) or 8 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
13
NET SPAN (CM)
100x200
295×255
SERIES
295 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
283x233x210h
EXTERNAL DIMENSIONS
295x255x255h
TROLLEY CAPACITY
15 (60x40) or 9 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
13
NET SPAN (CM)
100x200
295×295
SERIES
295 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
283x273x210h
EXTERNAL DIMENSIONS
295x295x255h
TROLLEY CAPACITY
24 (60x40) or 12 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
13
NET SPAN (CM)
100x200
295×335
SERIES
295 Series
OPERATING TEMPERATURE (°C)
-9° / +45°
INTERNAL DIMENSIONS
283x313x210h
EXTERNAL DIMENSIONS
295x335x255h
TROLLEY CAPACITY
24 (60x40) or 12 (60x80)
VOLTAGE
400V - 3 - 50Hz
POWER (KW)
13
NET SPAN (CM)
100x200